Bonding and Fastening Magnets in Assemblies: Adhesives, Tolerances and Durability

Magnet bonding and mechanical fastening are crucial aspects in the design of industrial assemblies. In electric motors, sensors, medical devices and automated equipment, the structural stability of the magnets directly affects the durability, reliability and safety of the entire system.

To select the correct adhesive, tolerances and retention system, contact the CIBAS technical team.

Although magnet bonding using resins and adhesives is the most common solution for minimising space requirements, several other fastening methods—including mechanical and interference-fit systems—ensure the integrity of the magnet bond and assembly structure even under the most extreme operating conditions. To place these techniques within the complete design and manufacturing process, read our guide to industrial magnetic assemblies.

In this guide, we examine the selection of adhesives for industrial magnets, tolerance management and the main mechanical alternatives for securing magnets.

Selecting an Adhesive for Magnets

Choosing a suitable magnet adhesive requires careful analysis of the product chemistry, the substrate material—such as steel, aluminium or plastic—and environmental stresses.

The main adhesive systems used in industrial assemblies are:

  • Epoxy Adhesives (One- and Two-Component): The preferred choice for high-performance applications. They provide high mechanical strength, chemical stability and thermal resistance up to and beyond 150–200°C.
  • Structural Acrylic Adhesives: Ideal for rapid curing and their ability to absorb severe impacts and vibrations.
  • Anaerobic Adhesives: Primarily used for coaxial fastening, such as inside rotors or stators, where the clearance between components is minimal and the absence of air triggers curing.
  • Toughened Cyanoacrylates: Suitable for rapid positioning or light loads.

Surface Preparation and Treatments

When bonding is used, either alone or in combination with mechanical elements, surface condition is critical. Neodymium (NdFeB) magnets are susceptible to oxidation and are therefore supplied with protective coatings such as Ni-Cu-Ni, epoxy or zinc.

To maximise adhesion:

  • Thorough Degreasing: Remove oils and residues using suitable solvents, such as isopropyl alcohol, or ultrasonic cleaning.
  • Surface Activation: Plasma or corona treatments increase the surface energy of epoxy coatings or plastic substrates.
  • Mechanical Pretreatment: Light, controlled sandblasting increases the surface area available for mechanical adhesion.

Managing Mechanical Tolerances and Bondline Thickness

Whether bonding or mechanical fastening is used, magnet manufacturing tolerances must be accounted for during the design stage.

  • Bondline Thickness: Industrial magnet adhesives require an optimum thickness, usually between 0.05 and 0.2 mm. If the fit is too tight, the adhesive may be scraped away during insertion, leaving uncovered areas.
  • Material Shrinkage: Volumetric shrinkage during adhesive curing and the different coefficients of thermal expansion (CTE) of the magnet and metal require a joint capable of absorbing residual stresses without causing microcracks in the magnet.

Bond Strength and Long-Term Stability

To ensure maximum magnet bond strength throughout the component’s service life, the design must provide:

  • Resistance to Thermal Cycling: Sufficient elasticity to compensate for differential thermal expansion.
  • Chemical and Environmental Resistance: Protection against the ingress of oils, coolants, moisture or salt spray, which could damage the adhesive layer or initiate subsurface magnet corrosion.
  • Dynamic Loads: High resistance to shear, impact and peel forces to withstand continuous acceleration and vibration.

Alternative and Complementary Mechanical Fastening Methods

In many industrial applications, bonding is supplemented or replaced by mechanical retention systems. These are essential when centrifugal forces, thermal stress or aggressive fluids could compromise the adhesive.

Direct Mechanical Retention (Pockets, Clips and Brackets)

  • Shaped Pocket Assembly: Magnets are inserted into cavities machined from solid material or formed within laminated stacks, where the mechanical wall prevents radial or tangential movement.
  • Clips, Springs and Retaining Brackets: Elastic stainless-steel or brass components apply a constant load to the magnet, securing it to the structure without overstressing it.
  • Through Bolts or Pins: Mainly used with ferrite or samarium-cobalt magnets featuring countersunk holes, with particular care taken during tightening because of the material’s brittleness.

Welding the Enclosure and Containment Structure

Directly welding a sintered magnet is not feasible because of its ceramic or intermetallic nature and extreme brittleness. Welding is, however, widely used to seal the enclosure surrounding it. During this process, it is essential to monitor the Curie temperature to prevent heat-induced demagnetisation:

  • Laser Welding of the Enclosure: Stainless-steel sleeves or housings can be sealed around the magnets. The laser beam concentrates energy on a microscopic point, limiting heat input and preventing damage to the internal magnet.
  • Ultrasonic Welding for Plastics: Used when the magnet is placed inside a thermoplastic shell. High-frequency vibrations locally melt the plastic, sealing the magnet within milliseconds without generating harmful heat.
  • Micro-Pulsed TIG or Resistance Welding: Used to secure metal end plates on rotors or sealed housings.

Overmoulding and Encapsulation

  • Plastic Overmoulding: The magnet is positioned inside a mould and encapsulated with high-performance polymers such as PA66, PPA or PPS. This method provides complete corrosion protection and continuous mechanical retention.
  • Complete Resin Potting: The entire assembly is immersed in a liquid resin that hardens around the magnets, fully encapsulating them and eliminating voids.

Fastening magnets within an assembly requires an integrated engineering approach, from choosing between magnet adhesives and mechanical retention systems to calculating tolerances and preparing surfaces. The right combination of chemical and mechanical fastening ensures high performance and maximum durability, even in the most demanding industrial applications.

To identify the fastening method best suited to your application’s operating conditions, contact the CIBAS team.